Aparatura do chromatografii HPLC oraz GPC/SEC
JĘZYK

Analizator tlenku azotu - NOA280i

Nitric Oxide Analysis

GE Analytical Instruments manufactures the Sievers Nitric Oxide Analyzer (NOA) for nitric oxide research and analysis. In biological systems, nitric oxide is produced from the enzymatic oxidation of arginine. Three isoforms of the enzyme nitric oxide synthase (NOS) have been identified in many cell types: endothelial NOS, neuronal NOS, and inducible NOS. The biological functions of NO include action as a vasodilator, neurotransmitter, cytotoxic agent, inhibit of platelet aggregation, and activator of smooth muscle proliferation.

Nitric oxide is also present in exhaled breath and may be a useful marker of airway inflammation.

In solution, nitric oxide reacts with molecular oxygen to form nitrite (NO2-), and with oxyhemoglobin and superoxide anion (O2-) to form nitrate (NO3-). NO also reacts with thiols to form S-nitroso compounds, amines to form nitrosamines, and metals to form metal nitrosylcomplexes.

The Sievers Nitric Oxide Analyzer (NOA 280i) offers the most versatile detection system for Nitric Oxide (NO) analysis. Employing GE Analytical Instruments' highly sensitive, ozone-chemiluminescence technology, the NOA 280i has unsurpassed versatility for liquid and exhaled breath NO measurement. With over 600 publications using the Sievers Nitric Oxide Analyzer, the NOA has proven to be the instrumentation of choice by researchers worldwide.

Overview

The Sievers Nitric Oxide Analyzer (NOA 280i) offers the most versatile detection system for Nitric Oxide (NO) analysis. Using GE Analytical Instruments' highly sensitive, ozone-chemiluminescence technology, the NOA 280i has unsurpassed versatility for liquid and exhaled breath nitric oxide (NO) measurement. With over 700 publications using the Sievers Nitric Oxide Analyzer, the NOA 280i has proven to be the instrumentation of choice by researchers worldwide. The Sievers NOA can be used to measure liquid samples or exhaled breath samples of nitric oxide.

Liquid Samples

The NOA 280i measures nitric oxide, nitrite, nitrate or nitrosothiols in most biological samples. Concentrations, ranging from low nanomolar to millimolar levels, can be measured in sample volumes ranging from a few microliters to several milliliters.

Exhaled Breath Samples

Exhaled nitric oxide can easily be measured with the NOA 280i. Fast response time and low sample flow rates allow for measurement of exhaled NO in humans and animals.

ANTI-FOAMING AGENT FOR PURGE SYSTEM

1 mL of concentrated anti-foaming agent (dilute 1:30 for use) Part Number: CNIP 00013 czytaj więcej

INSPIRATORY FILTER

Filter to provide < 5 ppb NO level in the inspired air. Part Number: CAFL 01410-01 czytaj więcej

BACTERIAL/VIRAL FILTERS

m filtration media. Part Number: CAFL 01420-01 czytaj więcej

PARTICLE FILTER - WHITE

For Gas Sampling Line. Should replace if pressure drop across reaction cell is greater than 0.1 Torr when filter is on versus when it is off, or should be changed every 6 months, whichever is sooner. Part Number: CHFL 01410 A czytaj więcej

PARTICLE FILTER - GREEN

Filter for Breath Pressure Line. Should be changed every 6 months. Part Number: CHFL 01430 A czytaj więcej

NO CALIBRATION GAS, DISPOSABLE TANK

Nitric Oxide calibration gas (45 ppm) for gas analysis applications. Part Number: CNDK 01400 czytaj więcej

Nitric Oxide calibration gas (45 ppm) for gas analysis applications.

Removes NO from ambient air providing a clean (< 1 ppb nitric oxide) air source for calibration. Part Number: CACT 01400-01 czytaj więcej

FRIT RESTRICTOR 200 ML/MIN

One included with instrument. Part Number: CHMI 14151-01 czytaj więcej

CHEMICAL TRAP

Hopcalite chemical trap replacement for vacuum pump. Part Number: CACT 00090-01 czytaj więcej

REPLACEMENT ODOR FILTER

Replacement odor filter for NOA. Part Number: CACT 01450-01 czytaj więcej